navigation bypass navigation contact us ring status schedules user guide links notices user sites people and policies jobs MicroWorlds publications meetings microscopes specifications About the ALS science highlights ALSNews home
 

 

 

Beamline 10.3.2

Environmental and Materials Science,
Micro X-Ray Absorption Spectroscopy

Operational

Now

Source characteristics

Bend magnet (beamline optics collect 0.166 horizontal mrad)

Energy range

2.5–17 keV

Monochromator

White light and monochromatic, with Si(111) two-crystal, constant exit monochromator

Calculated flux (1.9 GeV, 400 mA)

1 x 1010 photons/s/0.03%BW into 5-µm spot

Resolving power (E/DE)

7000

Endstations

Hutch with optical table

Characteristics

Sample mounted on x-y translation stage

Detectors

Seven-element Ge solid-state detector

Spot size at sample

Adjustable from 3 x 3 µm (slit down) up to 16 x 6 µm (full flux)

Samples

Format

Solids

Sample environment

Air

Experimental techniques

Custom designed for micro x-ray absorption spectroscopy

Local contact/spokesperson

Name: Matthew Marcus
Affiliation: Advanced Light Source, Berkeley Lab
Phone: (510) 486-5787
Fax: (510) 486-7696
Email: mamarcus@lbl.gov

Beamline phone number

(510) 495-2104

Table of all beamlines