|
Operational
|
1998
|
|
Source characteristics
|
16-cm-period wiggler (W16)
|
|
Energy range
|
7 - 14 keV
|
|
Monochromator
|
Single crystal, cylindrically bent
|
|
Calculated flux (1.9 GeV, 400 mA)
|
8.5 x 1013 photons/sec/0.1%BW at 12 keV (energy dependent)
|
|
Resolving power (E/DE)
|
~6000 with Si(111) at 10° asymmetry angle
|
|
Endstation
|
Macromolecular crystallography facility
|
|
Detectors
|
CCD (planned)
|
|
Spot size at sample (FWHM)
|
0.7 mm (h) x 0.3 mm (v)
|
|
Samples
|
|
Format
|
Single crystals of biological molecules
|
|
Preparation
|
Support labs available
|
|
Sample environment
|
Ambient or ~100°K
|
|
Special notes
|
Computers for data processing and analysis are available
|
|
Scientific applications
|
Biological crystallography; monochromatic
|
|
Local contact/spokesperson
|
Name: Thomas Earnest
Affiliation: Physical Biosciences Division,
Berkeley Lab
Phone: (510) 486-4603
Fax: (510) 486-5664
Email: tnearnest@lbl.gov
|