Beamline 9.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operational |
Now |
Source characteristics |
10-cm-period undulator (U10) |
Energy range |
10-800 eV |
Monochromator |
Either none or an off-axis zone-plate monochromator that will provide a focused beam with bandwidth of about 0.1% |
| Calculated flux (1.9 GeV, 400 mA) |
2.8 x 1015 photons/s/1%BW/central cone at 457 eV |
| Resolving power (E/ΔE) |
70 (undulator peak width) |
Endstations |
General purpose |
Detectors |
Scintillator plus CCD, photodiode, etc. |
Samples |
|
| Format |
Various |
| Preparation |
Can be cryo |
Sample environment |
Clean high vacuum |
Special notes |
Endstation separated from beamline by cooled window |
Experimental techniques |
Coherent scattering, holography, diffraction, correlation spectroscopy |
Local contact |
Name: Stefano Marchesini |
Spokesperson |
Name: Stephen Kevan |
Operational |
Now |
Source characteristics |
10-cm-period undulator (U10) (fundamental) |
Energy range |
5-30 eV |
Undulator beam |
White beam (straight undulator beam) |
Calculated flux (1.9 GeV, 400 mA) |
1016 photons/s/2.5%BW |
Spot size at sample |
400 (h) x 350 (v) µm |
| Monochromator #1 | 3-m Off-plane Eagle |
Calculated flux (1.9 GeV, 400 mA) |
1014 photons/s/0.1%BW |
Spot size at sample |
170 (h) x 50 (v) µm |
| Monochromator #2 | 3-m Off-plane Eagle |
| Calculated flux (1.9 GeV, 400 mA) | 1014 photons/s/0.1%BW |
| Spot size at sample | 560 (h) x 350 (v) µm |
Endstations |
Molecular-beam photoelectron/photoion spectroscopy |
| Local contact | Musa Ahmed
Phone: (510) 486-6355 Fax: (510) 486-5311 |
| Beamline Director | Stephen Leone
Affiliation: Univ. of California, Berkeley Phone: (510) 486-4754 Fax: (510) 495-2690 |
Beamline phone number |
(510) 495-2092 |
|
Molecular-beam photoelectron/photoion imaging and spectroscopy |
|
Characteristics |
Multipurpose design for photoion and photoelectron imaging and photoelectron/photoion coincidence experiments |
Detectors |
Time-of-flight 2-D position-sensitive detectors |
Samples |
|
| Format |
Gas sample |
| Preparation |
Molecular beam, seeded in rare gas |
| Sample environment | Vacuum ~10-5 Torr |
Scientific applications |
Spectroscopy and dynamics of clusters, radicals, metastable, and other novel species; fundamental understanding of excitation and relaxation processes in finite-sized many-body systems |
Local contact |
Musa Ahmed |
Table of all beamlines
Diagram of all beamlines